技术方法

四价HPV疫苗比活性检测方法初步建立及验证

展开
  • 1成都生物制品研究所有限责任公司质量检定室, 成都 610023; 2成都生物制品研究所有限责任公司生物技术研究室, 成都 610023

网络出版日期: 2026-10-12

Preliminary establishment and validation of a specific activity detection method for quadrivalent HPV vaccine

Expand
  • 1 Quality Control Laboratory, Chengdu Institute of Biological Products Co., Ltd., Chengdu 610023, China;2 Biotechnology Research Laboratory, Chengdu Institute of Biological Products Co., Ltd., Chengdu 610023, China

Online published: 2026-10-12

摘要

目的 建立并验证适用于四价HPV疫苗主要抗原组分衣壳蛋白L1的比活性检测方法。方法 采用双抗夹心ELISA,以四参数逻辑斯谛模型拟合标准曲线,建立HPV疫苗比活性检测方法;通过专属性、线性、准确度、中间精密度、检测范围及方法适用性实验,对该方法进行系统验证。结果 HPV6/11/16/18型ELISA检测试剂盒的专属性合格,各型别检测无交叉反应;线性关系均良好,决定系数均≥0.99;重复性相对标准偏差均≤15%,中间精密度相对标准偏差均≤20%;在抗原含量15.625~16 000.000 ng/mL范围内,加标回收率均值为98%~110%,各型别加标回收率的相对标准偏差均≤12%。检测不同批次疫苗单价原液及洗脱物样品,其比活性均满足合格标准。结论 建立的HPV L1抗原比活性的双抗夹心 ELISA检测法专属性、线性、重复性、准确度及中间精密度良好,可用于四价 HPV 疫苗单价原液及生产过程控制样品的抗原比活性检测,为疫苗生产工艺监控及终产品质量评估提供技术保障。

本文引用格式

苟林凤, 施慧敏, 司琪, 谢琴, 罗明杰, 吕冰凌, 赵荣丽, 李路 . 四价HPV疫苗比活性检测方法初步建立及验证[J]. 国际生物制品学杂志, 2026 , 49(5) : 330 -336 . DOI: 10.3760/cma.j.cn311962-20260120-00003

Abstract

Objective To establish and validate a specific activity detection method for the major antigen capsid protein L1 of quadrivalent HPV vaccine.Methods A double-antibody sandwich ELISA was used to construct the HPV vaccine specific activity detection system, using four-parameter logistic model for standard curve fitting. The method was systematically validated through tests of specificity, linearity, accuracy, intermediate precision, detection range, and method applicability.Results The HPV6/11/16/18 ELISA detection kits showed qualified specificity without cross-reactivity between different genotypes. The specific activity ELISA detection method showed good linear relationships for all types, with all coefficients of determination ≥ 0.99. The relative standard deviations (RSDs) of repeatability were ≤ 15% for all types, and RSDs of intermediate precision were ≤ 20% for all types. Within the antigen concentration range of 15.625-16 000.000 ng/mL, all average spiked recovery rates were within 98%-110%, and RSDs of spiked recovery rates for all types were ≤ 12%. The speciific activities of monovalent bulk samples and elutes from different vaccine batches all met quality standards.Conclusion The established double-antibody sandwich ELISA for specific activity detection of HPV L1 antigen has good specificity, linearity, repeatability, accuracy, and intermediate precision, and can be used for the detection of antigen specific activity in quadrivalent HPV vaccine monovalent bulk and production process control samples, providing technical guarantee for vaccine production process monitoring and final product quality evaluation.
文章导航

/

〈 〉