聚偏二氟乙烯除菌过滤在流感病毒裂解疫苗半成品配制工艺中的可行性

展开
  • 上海生物制品研究所有限责任公司生产管理部, 上海 201403

网络出版日期: 2026-10-12

Feasibility of PVDF sterilizing filtration in the final bulk formulation process of Influenza Vaccine (Split Virion), Inactivated

Expand
  • Production Management Department, Shanghai Institute of Biological Products Co., Ltd., Shanghai 201403, China

Online published: 2026-10-12

摘要

目的 考察聚偏二氟乙烯除菌过滤在流感病毒裂解疫苗半成品配制工艺中的可行性。方法 使用聚偏二氟乙烯除菌滤器对流感病毒裂解疫苗半成品实施除菌过滤工艺验证,开展滤器兼容性测试、吸附试验、细菌截留有效性验证,并考察除菌过滤后半成品的质量参数。结果 在现有工艺条件下,过滤后样品的泡点、流量时间、重量及外观均符合可接受标准,表明滤器与样品兼容性良好。除菌过滤后,样品的血凝素含量和蛋白质含量均在未过滤样品的96%~104%范围内,吸附影响较小。0.22 μm聚偏二氟乙烯除菌过滤滤器可完全截留半成品中的缺陷短波单胞菌。除菌过滤前后半成品各型血凝素含量和蛋白质含量差异均无统计学意义(t=0.04~1.81,均P>0.05),聚山梨酯80残留量在过滤后有所下降(t=6.93,P<0.05)。未见除菌过滤对半成品主要质量属性产生不利影响。除菌过滤后半成品的均一性和有效期均符合质量要求。结论 聚偏二氟乙烯除菌过滤适用于流感病毒裂解疫苗生产工艺,为该疫苗半成品配制增加除菌过滤工序积累了关键数据。

本文引用格式

张亮, 季伟, 任丽, 杜赟晖, 柳伟君 . 聚偏二氟乙烯除菌过滤在流感病毒裂解疫苗半成品配制工艺中的可行性[J]. 国际生物制品学杂志, 2026 , 49(5) : 307 -312 . DOI: 10.3760/cma.j.cn311962-20260319-00017

Abstract

Objective To investigate the feasibility of using polyvinylidene fluoride (PVDF) membrane sterilizing filtration during the production of the final bulk of Influenza Vaccine (Split Virion), Inactivated (Flu Vac).Methods PVDF sterilizing-grade filters were used to perform sterilizing filtration on the final bulk of Flu Vac. Filter compatibility, adsorption of vaccine components, bacterial retention, and product quality parameters of the Flu Vac final bulk after sterilizing filtration were measured.Results Under the established process conditions, the bubble point, flow time, weight, and appearance of the filtered samples all met the acceptance criteria, indicating good compatibility between the filter and samples. After sterilizing filtration, both hemagglutinin and protein contents of samples remained within 96%-104% of those in unfiltered samples, indicating minimal adsorption. The 0.22 μm PVDF sterilizing filter completely retained Brevundimonas diminuta in the final bulk of Flu Vac. There were no statistically significant differences between the hemagglutinin content of any influenza strain or the protein content before and after filtration (t=0.04-1.81, all P>0.05), whereas residual polysorbate 80 decreased after filtration (t=6.93, P<0.05). No adverse effects on the major quality attributes of the final bulk were observed. In addition, the homogeneity and shelf-life of the final bulk after sterilizing filtration met the established quality requirements.Conclusion PVDF sterilizing filtration is suitable for Flu Vac production, providing key data for the addition of sterilizing filtration step in the formulation of Flu Vac final bulk.
文章导航

/

〈 〉